Pole Mount Transformer Wiring Diagram
Tap changers compensate for small voltage variations along the distribution system.
Pole mount transformer wiring diagram. Figure 15 1 shows distribution transformers in stock at an electric utility company ser vice building. Open wye open delta transformer banks mounting dimensions three phase transformer banks general policies three phase transformer bank mounting dimensions three phase platform mounting of transformers all voltages section 6 pole mounted transformers table of contents 06 03 01a 06 03 01b 06 06 04 06 07 06a 06 07 06b 06 07 10a 06 07 10b 06 06 01. C substation standards mimic bus color standard 64. 15 4 vault or network type fig.
Wiring diagram book a1 15 b1 b2 16 18 b3 a2 b1 b3 15 supply voltage 16 18 l m h 2 levels b2 l1 f u 1 460 v f u 2 l2 l3 gnd h1 h3 h2 h4 f u 3 x1a f u 4 f u 5 x2a r power on optional x1 x2115 v 230 v h1 h3 h2 h4 optional connection electrostatically shielded transformer f u 6 off on m l1 l2 1 2 stop ol m start 3 start start fiber optic. Mild steel tank with welded lifting lugs and hanger brackets for direct to pole mounting. Spin top bushings for either cover or side wall mount. Provide you with reliable and cost effective transformer products matched to your system requirements.
The distribution transformers available for use for various applications as shown include pole type figs. A dual voltage switch permits use of the same transformer on. These harmonics can cause interference in nearby communication circuits as well as other assorted power quality problems. Figure 4 wye wye transformer connections diagram click to expand diagram one problem inherent to wye wye transformers is the propagation of third harmonic currents and voltages.
E substation standards transformer sudden pressure relay schematic diagram 62. 15 2 and 15 3 pad mounted fig. Are they all connected to the 3 wire terminals. 5 bracket cutout mounting pole 563222 1 1 1 1 1 6 wire 4 awg cu bare 610208 40 40 40 40 40 7 wire 4 awg cu soft drawn poly insulated ft 611442 8 8 8 8 8 8 cutout 27 kv polymer 013739 1 1 1 1 1 9 fuse link 3t rated 683706 1 9 fuse link 6k rated 683708 1.
I have a question regarding distribution transformer mounted on a pole neighborhood how are more than one house wired to a distribution transformer on the pole. The externally operated tap changer is a single phase five position design for de energized operation. Some details on this would be great. 15 5 and submersible fig.
A single phase as is the case in one pole mounted distribution transformer as well uses the neutral from a three phase system. Standard features meets or exceeds current rus nema and ansi standards c57 12 00 ansi c57 12 20 as applicable. Bushing for cover mounting.