12 Lead 480 Volt Generator Wiring Diagram
480 volt motor wiring diagram by.
12 lead 480 volt generator wiring diagram. Variety of 12 volt generator wiring diagram. A wiring diagram is a simplified conventional pictorial representation of an electrical circuit. Saturday february 10 2018 edit. Home 480 volt 12 lead motor wiring diagram 480 volt 3 phase motor wiring diagram 480 volt motor starter wiring diagram.
Then something is very wrong. 480 277 600 346 2400 1386 33001905 41602402 6600 3811 138007967 50 380219 400 231 415240. You can achieve this with a 3 phase generator either by using a changeover switch or getting a dual voltage generator that is already made for that purpose. J single phase kw kva ratings are approximately equal to 50 of the generator s three phase ratings.
12 lead technical data connection diagrams series high wye parallel low delta l3 l2 l1 l l0 l l0 l l l0 t9 t6 t3 t11 t8 t5 t2 t10 t7. I have a harbor freight 120 volt generator. The motor will supply the same amount of power but with a different. Reason being the wiring diagram is an as wired.
10 and 12 lead high wye available voltages iso standard 10 lead generators are identical to 12 lead generators with the exception that u6 v6 and w6 are permanently bonded together as n 480v connections shown in blue 416v connections shown in red u n v u2 v v v v w u6 u1 v1 v2 v5 v6 w1 w2 w6 w5 480v 416v u5 v v. Electrical motors 12 lead dual voltage wye start delta run both voltages or 6 lead single voltage wye start delta run motors designed by us motors for wye start delta run may also be used for across the line starting using only the delta connection. Always use wiring diagram supplied on motor nameplate. If you can read each individual stator lead at around 110 120 volts and you can arrange them both in series and even turn one winding around.
10 and 12 lead high wye available voltages technical data marathon generators marathon generator catalog chudov 3 phase motor wiring diagram 12 leads wiring diagram 3. On a 12 wire motor wired for high voltage i e 480v 10t 11t and 12t must be connected together but not connected to anything else. This can include electric motors running at 480 volt appliances and production equipment using 208 volt and smaller loads and power tools at 240 volt. Time lapse of schematic diagram drawn into a wire diagram and the.
The other 9 wires would be connected as in a 9 wire motor note in a 9 wire motor the equivalent of t10 t11 and t12 are internally connected together. L1 to t1 l2 to t2 l3 to t3 t4 to t7 t5 to t8 and t6. It reveals the elements of the circuit as streamlined shapes and also the power as well as signal links between the devices.